REASONS WHY AN IP PAGING SYSTEM IS IMPORTANT FOR MODERN COMPANIES

Reasons Why an IP Paging System is Important for Modern Companies

Reasons Why an IP Paging System is Important for Modern Companies

Blog Article

Network PA System for tool to massive jobs



Introduction


The XC-9000 system is a fully digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP method, the system guarantees the efficient and right transmission of all data packets. Not just can it utilize existing computer system networks, such as LANs or the Internet, to transfer broadcast signals, but also it can likewise be deployed on a devoted broadcasting network.


A single-server system can sustain up to 3000 terminals and enables for web server cascading. There are no restrictions on the concurrent program networks, accomplishing real full digital broadcasting.


System Characteristics.



Flexible PA System Style


The PA system design is easy, including solution management software, network microphones, network amplifiers, network speakers, and various other devices.All equipment is connected using the TCP/IP intranet protocol, permitting for adaptable setup and very easy administration of the system, with free control over broadcast material, network tools, and regions with the network.


Comprehensive Sound Monitoring


The audio monitoring software program includes integrated features for producing broadcast strategies, flexible zoning, and pre-scheduled broadcasts.It sustains 24-hour shows, enabling changing setups throughout all day


Versatile Audio Source Assistance


The system sustains numerous kinds of audio sources for sending out notices like online speech and BGM playback. Audio resources can originate from electronic music applications, CD/DVD gamers, microphones, etc. Furthermore, the system gives diverse functions of sustaining different broadcasting attributes such as arranged broadcasting, zoned broadcasting, and emergency broadcasting.


Smoke Alarm System Combination


The system has an emergency alarm function and can be integrated right into a smoke alarm system. When the alarm central unit obtains the alarming signals, the cable television will send the signal to devices, which triggers the XC-9000, sending out signals to audio speakers


Individuals might select to predetermined settings to trigger full-area or zoned alarms in emergencies. The alarm voices been available in numerous forms and could be modified accommodating demands. For instance, customers can transform language setups, upload and edit their audio resources according to specific demands, such as intruding alarm systems, emergency alarm or air aid alarm systems, and so on





Emergency Alarm System Integration


The system has a fire alarm feature and can be integrated right into a fire alarm system. When the alarm central unit receives the startling signals, the wire will certainly send the signal to tools, which triggers the XC-9000, sending signals to speakers


Customers might pick to preset settings to turn on full-area or zoned alarm systems in emergency situations. The alarm system voices been available in multiple forms and can be edited accommodating needs. For instance, individuals can alter language settings, upload and modify their audio sources according to precise demands, such as intruding alarm systems, emergency alarm or air help alarm systems, etc





App Control for System Workflow


The system enables mobile app login and use, permitting users to initiate broadcasts and various other procedures to licensed terminals through the web server software application, guaranteeing a structured and hassle-free experience.


Integrated SIP Compatibility


The system not only enables SIP phones to visit, but likewise can be connected to third-party SIP web server or IPPBX, which establishes an entirely incorporated and compatible interaction system through smooth assimilation right into existing systems.


Open up SDK


When big project like smart park takes place, the system supplies an open SDK integrated right into third-party application systems


System Infrastructure



Main Features




Arranged Playback


The system is able to instantly relay according to the set up tasks as long as individuals post the audio declare each amount of time of the day to the web server and develop a playback routine.


Zone Broadcasting




The system can randomly split a couple of network devices right into various areas to play specified audio programs or send out announcements to any assigned location. The volume of each device can be from another location readjusted.


Real-time Broadcasting


The system can capture and transmit radio programs or other external audio sources in real-time, and at the very same time transmitted them in sync.


Emergency Alarm Assimilation


The system can be integrated with the fire alarm system for control. When a fire alarm signal is caused, it immediately activates the emergency situation broadcast feature and supports nearby flooring alarms. It also permits hands-on emergency broadcasting by clicking a single switch.


SIP Phone Assimilation


The system can be integrated with SIP servers, allowing online speech of voice broadcasting through SIP phones to send announcements anytime and anywhere.


CCTV Combination


The electronic tools such as IP POE Audio speakers takes on the worldwide common ONVIF method, which enables their voices to be relayed by means of VMS platforms. The terminals can additionally be integrated with CCTV systems for synchronized program.


Main Products.



Sound Monitoring Software XC-9000


B/S style, sustains cross-platform applications.
Covers standard broadcasting system functions, allowing for dividers administration.
Unified management of terminals within the system, seeing work standing, and set quantity modification, and so on.
Supports structure multi-level web server designs, releasing management according to individual geographical regions.
Provides SDK growth packages for secondary development and assimilation with various other system platforms.


Network Paging Console XC-9038N


Power: DC12V/1.5 A.
Display: 4-inch touchscreen, resolution 480 * 480.
Communication Protocols: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Frequency Response: 100Hz~ 16KHz.
Operating Temperature: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Paging Console XC-9037N


Power Supply: DC12V/1.5 A.
Show: 4-inch touchscreen, resolution 480 * 480.
Communication Procedures: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 80dB.
Regularity Response: 100Hz~ 16KHz.
Running Temperature level: 0~ 45 ℃.
Measurements: 144 * 144 * 34.1 mm.


Network Horn Speaker GEN-6391A03


Power Supply: DC24V/2.7 A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Proportion: > 80dB.
Regularity Reaction: 100Hz~ 18KHz.
Intercom: Supported, Integrated Microphone.
Running Temperature: -20~ 50 ℃.
Dimensions: 283.1 * 224.3 * 269mm.


Network Ceiling Speaker GEN-6211A03


Power Supply: DC 24V/1A or POE.
Interaction Methods: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Frequency Reaction: 100Hz~ 18KHz.
Running Temperature level: -20 to 50 ° C.
Dimensions: φ213 x 165mm.


Network Wall Mount Audio Speaker GEN-6011A03


Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP, ONVIF.
Signal-to-Noise Ratio: > 80dB.
Regularity Feedback: 100Hz~ 18KHz.
Operating Temperature: -20~ 50 ℃.
Dimensions: 193x151.5 x292mm.


Network Column Audio Speaker GEN-6191A03


Power Supply: DC24V/1A or POE.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Ratio: > 90dB.
Regularity Feedback: 45Hz~ 18KHz.
Operating Temperature: -10~ 55 ℃.
Dimensions: 296x140x130mm.


Network Audio Bridge GEN-3101A01


Power Supply: POE.
Interaction Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 85dB.
Regularity Reaction: 50Hz~ 20KHz.
Running Temperature: -10~ 55 ℃.
Dimensions: 126x66x27mm.


Network Digital Amplifier XC-9508P


Power Supply: AC100V~ 240V, 50/60Hz.
Power: 130W, 260W, 360W, 500W.
Communication Method: TCP/IP, UDP, SIP.
Signal-to-Noise Proportion: > 80dB.
Frequency Feedback: 60Hz~ 18KHz.
Operating Temperature level: -10~ 50 ℃.
Dimensions: 440x300x44mm.


Area Combining Digital Amplifier NBS-2301


Power Supply : A/C 220V, 50Hz.
Power : 130W , 260W , 360W , 550W , 700W.
Communication Method : HTTP, TCP/IP, UDP, ARP, ICMP, IGMP.
Signal-to-Noise Proportion :.
Mic Input 01: ≥ 65dB,.
Mic Input 02/03: ≥ 80dB,.
Aux Input 01/02: ≥ 82dB.
Regularity Reaction :.
Mic Input 01: 80Hz~ 14kHz.
Mic Input 02/03: 60Hz~ 16kHz.
Aux Input 01/02: 60Hz~ 16kHz.
Operating Temperature level :.
10 ℃~ +50 ℃ (14 ℉~ 122 ℉)
Measurements : 483x430x88mm.


IP User Interface System NAC-5003


Power Supply: AC100V~ 240V, 50/60Hz.
Interaction Method: TCP/IP, UDP.
Interfaces: 1 Ethernet port, 32 alarm inputs, 8 alarm system outputs.
Operating Temperature level: -10~ 50 ℃.
Measurements: 483x259x44mm.


Spon CommunicationsIp Pa System

Remedy For School



Versatile Zoning Program:


The totally network terminals can understand versatile zoning options, allowing for transmitting alerts to different zones or individual terminals ( devices).


Institution Bell System:


Spon CommunicationsIp Paging System
It supplies school bell system at the beginning/ending of the class. Multiple circumstances can be developed, including various set up program jobs according to summer/winter timetable.


Fire Alarm System Assimilation


It supports combination with emergency alarm systems, enabling emergency alarm signals to be incorporated right into the PA system.


Class Sound Amplification


Terminals sustain day-to-day applications in class scenes. They can be linked to projectors or interactive white boards for audio amplification.


Smart Street Lamp/Security Pole



Assistance SIP Procedure:


Integrated SIP protocol for seamless integration with network communication systems.


VMS Operatings Systems Assimilation:




Integrated ONVIF method for assimilation with VMS platforms.


Third-Party Assimilation:


Integrated In HTTP API for integration with 3rd party systems.


Voice Alarm System Causing:


Constructed in alarm system input interface for setting off voice alarms with electronic cameras.


Option For Hotel



Zone Control by Flooring:


The system uses complete network setups, separating zones relying upon different floors and control over each area independently.


Fire Alarm System Integration:


The system can be incorporated with fire alarm system, enabling combination of fire alarm system signals into the broadcasting system.


Scheduled Broadcasting:


It sustains programmable scheduled broadcasting, enabling flexible arrangements according to various demands.


Emergency situation Broadcasting:


It supports emergency situation broadcasting for the entire location, allowing one-click emergency situation communication. - IP Speaker


Ip SpeakerIp Speaker

Option For Factory



Zone Broadcasting:


It enables relaying to any zone, guaranteeing no interference in between various areas.


Alarm system Triggering:


Terminals have numerous kinds of interfaces, making it possible for to trigger alarms when linked with electronic cameras.


All Network Instruments:


Implementation of fully network devices substantially reduces the trouble of operating such as examining devices on harmful websites, and thus shielding individuals and building.


The deployment of all network tools significantly reduces the trouble of procedure and maintenance management


Integrated SIP Phones:


The system can be integrated with SIP phone and program alerts using SIP phones at any kind of time and anywhere. Two-way audio talkback between SIP phones and IP POE Speakers makes it simple for inspecting gadgets sitting in office or various other workplaces.


The XC-9000 system is a totally digital network PA system based on the TCP/IP protocol. By leveraging the TCP/IP protocol, the system makes sure the correct and reliable transmission of all data packages. The system sustains different forms of audio sources for sending out notices like live speech and BGM IP PA System playback. In enhancement, the system supplies diverse features of sustaining various broadcasting features such as set up broadcasting, zoned broadcasting, and emergency situation broadcasting.


The system can be integrated with the fire alarm system for control.

Report this page